L1
L2
Inverter
AC Distribution Panel
NEUTRAL
GROUND
Neutral
HOT L1
HOT L2
Ground
AC LEGEND
AC Cable
Generator
Disconnect
G
N
L2
L1
System Control
Panel (optional)
Vented Battery
Enclosure
Battery Temperature Sensor
(BTS)
24-volt Battery Bank Enclosure
xantrex
Bypass
GEN
GRID
H
a
n
d
l
e
I
n
t
e
r
l
o
c
k
Bypass INV 1 OUT
INV IN
AC Breakers
Bypass
Utility
Grid
Grounding
Electrode
Conductor
Main
AC Distribution
Panel
H
a
n
d
l
e
I
n
t
e
r
l
o
c
k
Conext SW DC Switchgear
DC Disconnect
Battery
Negative
Battery
Positive
Xanbus Stacking REM BTS
N
120/240 Vac or
240 Vac only
AC Generator
Conext SW Inverter/Charger
Conext SW AC Switchgear
Negative (–)
Positive (+)
BATTERY
LEGEND
Ground
Bus Bar
Neutral-to-Ground
Bond inside.
NOTE: Be sure to check the
generator for a neutral-to-
ground bond and remove it.
There can only be one neutral-
to-ground bond in the system.
System Control Panel
Ente
r
Exit
Fault/Warning
System Status
Battery 20.4 A 53.9V
BatLev E --F
Load 1235W
AC 1 115 W 3202V
Menu
Standby
12: 00 AM Jan 01
INV OUT
Xanbus
Network
Terminator
This AC Switch is a
customer-supplied
component.
AC Switch
Battery
System
Ground
Connect to
inverter’s
Chassis
Bonding
Lug
The actual positions of the Neutral bus and the Ground bus may be different than what is shown here. This drawing is for illustration purpose only.
NOTE: If no Grid
is available, the
generator can be
connected to the
AC breakers in the
Conext SW AC
Switchgear,
instead of to a
separate AC
Generator
Disconnect.
The actual positions of the
Negative shunt and Ground bus
may be different than what is
shown here. This drawing is for
illustration purpose only.
Automatic Generator
Start (optional)
Xanbus
Network
Terminator
Power
Generator On
Network
Fault
Automatic Generator Start
Conext ComBox
(optional)
Communication Cable
(Category 5)
BTS
ACCESSORIES